VA 520 - Flowmeter
Xuất sứ: Germany
Nhà cung cấp: Anh Nghi Sơn – ANS VietNam
Hãng sản xuất: CS Instruments Viet Nam
VA 520 - Flowmeter Cs Instrument VietNam, Flowmeter VA 520 Cs Instrument, Cs Instrument Đại Lý Việt Nam.
Cs Instruments Vietnam. Nhà cung cấp Anh Nghi Sơn - ANS Viet Nam.
Cung cấp tất cả máy móc, thiết bị của Cs Instruments Vietnam.
VA 520 - Mass Flow Meter for Compressed Air and Gas.
Our affordable mass flow meter for compressed air and gases works according to the approved calorimetric measuring principle. An additonal pressure and temperature compenstation is not necessary. Contrary to the previously used bridge circuit the newly developed evaluation electronics records all measured values digitally. This enables very precise and fast measurements.
Due to the new evaluation electronics, all VA 520 models have an integrated Modbus output as a standard. So all parameters can be easily transferred via Modbus.
Due to its compact design it is possible to monitor all compressed air systems from the compressor to the smallest compressed air tool (1/4“ to 2 inch) with the new mass flow sensor VA 520. VA 500 flow sensors are available for larger pipe diameters from DN 50 to DN 300. Apart from compressed air also other gases like e.g. nitrogen, oxygen and CO2 can be measured.
TECHNICAL DATA VA 520
Parameters: m³/h, l/min (1000 mbar, 20 °C) at compressed air or Nm³/h, Nl/min (1013 mbar, 0 °C) for gases
Units adjustable via keys at display: m³/h, m³/min, l/min, l/s, ft/ min, cfm, m/s, kg/h, kg/min, g/s, lb/min, lb/h
Sensor: Thermal mass flow sensor
Measuring medium: Air, gases
Gas types are adjustable over CS service software or CS data logger: Air, nitrogen, argon, helium, CO2, oxygen, vacuum
Measure range: See table above
Accuracy: (m.v.: of meas. value) (f.s.: of full scale) ± 1.5 % of m.v. ± 0.3 % of f.s. on request ± 1.0 % of m.v. ± 0.3 % of f.s.
Operating temperature: -30...80 °C
Operating pressure: -1 to 16 bar optional to PN 40
Digital output: RS 485 interface (Modbus-RTU), optional: Ethernet-Interface PoE), M-Bus
Analog output: 4...20 mA for m³/h e. g. l/min
Pulse output: 1 Pulse per m³ or per liter galvanically isolated. Pulse value can be set on the display. Alternatively, the pulse output can be used as an alarm relay
Supply: 18...36 VDC, 5 W
Burden: < 500 Ω
Housing: Polycarbonate (IP 65)
Measuring section: stainless steel, 1.4301 or 1.4571
Process connection: Flange (to DIN EN 1092-1 e. g. ANSI 150 Ibs or ANSI 300 Ibs)
Mounting position: Any
Dimension:
Stainless steel: 1,4301 | Order no. | ||
VA520 Flow meter with integrated 1/4", DN 8 measuring section 1,4301 | 0695 0520 | ||
VA520 Flow meter with integrated 1/2", DN 15 measuring section 1,4301 | 0695 0521 | ||
VA520 Flow meter with integrated 3/4", DN 20 measuring section 1,4301 | 0695 0522 | ||
VA520 Flow meter with integrated 1", DN 25 measuring section 1,4301 | 0695 0523 | ||
VA520 Flow meter with integrated 1 1/4", DN 32 measuring section 1,4301 | 0695 0526 | ||
VA520 Flow meter with integrated 1 1/2", DN 40 measuring section 1,4301 | 0695 0524 | ||
VA520 Flow meter with integrated 2", DN 50 measuring section 1,4301 | 0695 0525 | ||
Stainless steel: 1,4571 | |||
VA520 Flow meter with integrated 1/4", DN 8 measuring section 1,4571 | 0695 1520 | ||
VA520 Flow meter with integrated 1/2", DN 15 measuring section 1,4571 | 0695 1521 | ||
VA520 Flow meter with integrated 3/4", DN 20 measuring section 1,4571 | 0695 1522 | ||
VA520 Flow meter with integrated 1", DN 25 measuring section 1,4571 | 0695 1523 | ||
VA520 Flow meter with integrated 1 1/4", DN 32 measuring section 1,4571 | 0695 1526 | ||
VA520 Flow meter with integrated 1 1/2", DN 40 measuring section 1,4571 | 0695 1524 | ||
VA520 Flow meter with integrated 2", DN 50 measuring section 1,4571 | 0695 1525 | ||
Outer thread measuring section of VA 520 with stainless steel 1,4571 | |||
NPT outer thread | C2 | ||
Option signal output / bus connection: | |||
Standard | |||
Ethernet-Interface für VA500/VA520, FA500 | Z6955006 | ||
Ethernet-Interface PoE für VA500/VA520, FA500 | Z6955007 | ||
M-Bus (pulse output not available) | Z695 5004 |
Maximum pressure: | |||
40 bar (High-pressure) | Z695 0411 | ||
Surface condition: | |||
Special cleaning - oil and grease free (e.g. for oxygen) | 0699 4005 | ||
LABS free and silicone free version incl.cleaning oil and grease free | 0699 4007 | ||
Special measuring range: | |||
Special measuring range freely selectable | Z695 4006 | ||
Accuracy class: | |||
± 1 % of measured value (precision) | Z695 5005 | ||
Connection cables: | |||
Connection cable for VA/FA, 5 m, with M12 plug | 0553 0104 | ||
Connection cable for VA/FA, 10 m, with M12 plug | 0553 0105 | ||
Connection cable for VA/FA, 20 m, with M12 plug | 0553 0120 | ||
Ethernet-connection cable length 5 m, M 12 plug x-coded (8 poles) RJ 45 plug | 0553 2503 | ||
Ethernet-connection cable length 10 m, M 12 plug x-coded (8 poles) RJ 45 plug | 0553 2504 | ||
Cable for alarm-/pulse output for dew point sensors/ flow sensors with M12 plug, lenght 5 m | 0553 0106 | ||
Cable for alarm-/pulse output for dew point sensors/ flow sensors with M12 plug, lenght 10 m | 0553 0107 | ||
CS Service software incl. PC connection set for FA/VA 5xx sensors | 0554 2007 | ||
Closing cap for measuring section in aluminium | 0190 0001 | ||
Closing cap for measuring section stainless steel 1.4404 | 0190 0002 | ||
M12 – T plug for VA 500/520 to connect several sensors | 020000823 | ||
Mains units: | |||
Mains unit in wall housing for maximum 2 sensors of the series VA/FA 5xx, 100-240 V, 23 VA, 50-60 Hz / 24 VDC, 0.35 A |
0554 0110 | ||
AC adapter plug 100-240 V AC/ 24 V for VA/FA 500/520 | 0554 0109 | ||
External display, chart recorder DS 400 | 0500 4000 | ||
Calibration and adjustment: | |||
Real gas calibration for oxygen (O2) with cleaning - free of oil and grease | 3200 0010 | ||
5 point precision calibration of new instrument with ISO certificate | 3200 0001 | ||
Real gas calibration | 3200 0015 | ||
Real gas calibration for mixed gases | on request |